EVCO EVFTFT618N7U User Manual
Page 41
EVCO S.p.A.
EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224
Page
41
of
62
rL2
rL1
rL3
%
50
increase percentage 2nd proving step (with respect to
100%)
rL3
rL2
rL4
%
75
increase percentage 3rd proving step (with respect to
100%)
rL4
rL3
100
%
100
increase percentage 4th proving step (with respect to
100%)
rL5
rL4
rL6
%
- - - -
increase percentage 5th proving step (with respect to
100%)
rL6
rL5
rL7
%
- - - -
increase percentage 6th proving step (with respect to
100%)
rL7
rL6
rL8
%
- - - -
increase percentage 7th proving step (with respect to
100%)
rL8
rL7
rL9
%
- - - -
increase percentage 8th proving step (with respect to
100%)
rL9
rL8
rL10
%
- - - -
increase percentage 9th proving step (with respect to
100%)
rL10
rL9
100
%
- - - -
increase percentage 1oth proving step (with respect to
100%)
Par.
Min.
Max.
Unit
Default
Humidity regulator
rU0
0
1
- - - -
0
humidity management mode:
0 = with humidity probe
1 = at time cycles on the basis of the percentage set
rU1
-99
99
°C
0
Minimum temperature in the cabinet below which the
humidification/dehumidification control is prevented
rU2
1
600
sec
60
cycle time for switch-on of the humidifier (only for rU0 = 1,
see also uU3)
rU3
1
600
sec
30
humidifier switch-on time within the cycle time uU2 to
generate 100% humidity in the cabinet (only for rU0 = 1,
see also rU2)
rU4
0
1
- - - -
0
enabling of humidification/dehumidification control during
the block, storage and manual cooling phases
rU5
1
100
%r.H.
5
dehumidification differential
rU6
0
100
%r.H.
2
value of dehumidification neutral area
rU7
0
255
sec
10
dehumidification
attempt
duration
with
pump-down
electrovalve
rU8
1
100
%r.H.
5
humidification differential
rU9
0
100
%r.H.
2
value of humidification neutral area
rU1
0
0
50
%r.H.
10
value of humidification proportional band
rU1
1
0
255
s
30
cycle time for humidification proportional regulation
rU1
2
0
1
- - - -
0
base times for humidification proportional adjustment cycle
time: