beautypg.com

EVCO EVFTFT618N7U User Manual

Page 41

background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

41

of

62

rL2

rL1

rL3

%

50

increase percentage 2nd proving step (with respect to

100%)

rL3

rL2

rL4

%

75

increase percentage 3rd proving step (with respect to

100%)

rL4

rL3

100

%

100

increase percentage 4th proving step (with respect to

100%)

rL5

rL4

rL6

%

- - - -

increase percentage 5th proving step (with respect to

100%)

rL6

rL5

rL7

%

- - - -

increase percentage 6th proving step (with respect to

100%)

rL7

rL6

rL8

%

- - - -

increase percentage 7th proving step (with respect to

100%)

rL8

rL7

rL9

%

- - - -

increase percentage 8th proving step (with respect to

100%)

rL9

rL8

rL10

%

- - - -

increase percentage 9th proving step (with respect to

100%)

rL10

rL9

100

%

- - - -

increase percentage 1oth proving step (with respect to

100%)

Par.

Min.

Max.

Unit

Default

Humidity regulator

rU0

0

1

- - - -

0

humidity management mode:

0 = with humidity probe

1 = at time cycles on the basis of the percentage set

rU1

-99

99

°C

0

Minimum temperature in the cabinet below which the

humidification/dehumidification control is prevented

rU2

1

600

sec

60

cycle time for switch-on of the humidifier (only for rU0 = 1,

see also uU3)

rU3

1

600

sec

30

humidifier switch-on time within the cycle time uU2 to

generate 100% humidity in the cabinet (only for rU0 = 1,

see also rU2)

rU4

0

1

- - - -

0

enabling of humidification/dehumidification control during

the block, storage and manual cooling phases

rU5

1

100

%r.H.

5

dehumidification differential

rU6

0

100

%r.H.

2

value of dehumidification neutral area

rU7

0

255

sec

10

dehumidification

attempt

duration

with

pump-down

electrovalve

rU8

1

100

%r.H.

5

humidification differential

rU9

0

100

%r.H.

2

value of humidification neutral area

rU1

0

0

50

%r.H.

10

value of humidification proportional band

rU1

1

0

255

s

30

cycle time for humidification proportional regulation

rU1

2

0

1

- - - -

0

base times for humidification proportional adjustment cycle

time: