At the end, it shows the OFF label on display DS1 if EVFTFT618 is in standby, or it shows the cabinet temperature and the
current time on display DS6.
During setting of the set-point of a manual cooling cycle, the temperature set-point is displayed on DS1 and the humidity
set-point on display DS2 (if humidity control is envisioned, otherwise the display remains off). The other displays are off.
During the execution of the manual cooling cycle it shows the cabinet temperature on display DS1, the relative humidity
value or the humidity set-point on DS2 or the display remains off (depending on parameters rU0 and rU4), the current
time is on display DS6. The other displays are off.
During setting of the set-point of a manual heating cycle, the temperature set-point is displayed on DS1 and the humidity
set-point on display DS2 (depending on parameter rU0). The other displays are off.
During the execution of the manual heating cycle it shows the cabinet temperature on display DS3, the relative humidity
value or the humidity set-point on DS2 (depending on parameter rU0), the current time is on display DS6.
During setting of an automatic program, the following is displayed:
For the block phase, the cabinet temperature set-point is on display DS1, the humidity set-point on DS2 (if humidity
control is envisioned) and the duration is on display DS6
For the storage phase, the cabinet temperature set-point is on display DS1, the humidity set-point on DS2 (if humidity
control is envisioned)
For the recovery and proving phase, the cabinet temperature set-point on the display DS3, the humidity set-point on DS2
and duration on DS6
For the baking delay phase, the cabinet temperature set-point is on display DS3, the humidity set-point on DS2.
During execution of an automatic program, the following is displayed:
For the block phase, the cabinet temperature on the display DS1, the humidity set-point or the relative humidity on DS2
(depending on parameters rU0 and rU4), the program end day on display DS4, the program end month on DS5 and the
program end time on DS6;
For the storage phase, the cabinet temperature on the display DS1, the humidity set-point or the relative humidity on DS2
(depending on parameters rU0 and rU4), the program end day on display DS4, the program end month on DS5 and the
program end time on DS6;
For the recovery and proving phase, the cabinet temperature on the display DS3, the humidity set-point or the relative
humidity on DS2 (depending on parameter rU0), the program end day on display DS4, the program end month on DS5
and the program end time on DS6;
For the baking delay phase, the End label on DS1, the cabinet temperature on display DS3, the humidity set-point or the
relative humidity on DS2 (depending on parameter rU0), the current time is on DS6.
If defrosting is activated (manual or automatic), the display DS1 shows the DEF label for the entire duration of defrosting.
If an alarm occurs, the display DS1 shows the ALL label until any key is pressed.