beautypg.com

4 execution of an automatic cycle – EVCO EVFTFT618N7U User Manual

Page 22

background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

22

of

62

6.1.4 Execution of an automatic cycle

Below find the illustration of the complete navigation system during the execution of an automatic cycle.

Once the automatic cycle is started, the following screen is displayed:

Press the START/STOP key to start the cycle. Press the START/STOP key for 3 seconds to interrupt the cycle.

The BAKING DELAY key allows to enable/disable

phase 5 of the cycle during execution

Main outputs status bar

In this screen it is possible to display the active alarms and

non-active alarms

In this screen it is possible to modify the set-points. Scroll the set-points

to be modified using the UP and DOWN keys and proceed with the

modification using the + and - keys. Once the modification has been

completed, press BACK to return to the menu

In this screen it is possible to display the time at which each phase ends

Item present only during the phases in which the

possibility of activation is envisioned

Once manual defrosting is pressed, the same will

start. The defrost symbol will appear in the cycle in

progress window.

By pressing the MENU key, reach the OPTIONS

screen

The internal values can be displayed on this screen