RocketLinx ES7510-XT User Guide: 2000571
Rev. D
Modbus TCP Register Table - 207
ModBus TCP /IP Support
Modbus TCP Register Table
The latest firmware provides the initial release of the Modbus TCP/IP client service support for factory
automation applications. You can implement the modbus command using the command line interface in
console and Telnet modes, which allows you to modify some parameters such as, idle time, number of Modbus
masters, and the Modbus service port.
Note: The Modbus TCP client returns 0xFFFF to a Modbus master when pulling a reserved address.
05
Acknowledge
The slave has accepted the request and processing it, but a
long duration of time is required to do so.
06
Slave Device Busy
The slave is engaged in processing a long-duration program
command.
07
Negative
Acknowledge
The slave cannot perform the program function received in
the query.
08
Memory Parity Error
The slave attempted to read extended memory, but detected a
parity error in the memory.
Word Address
Data Type
Description
System Information
0x0000
16 words
Vender Name =
“Comtrol”
Word 0 Hi byte = ‘C’
Word 0 Lo byte = ‘o’
Word 1 Hi byte = ‘m’
Word 1 Lo byte = ‘t’
Word 2 Hi byte = ‘r’
Word 2 Lo byte = ‘o’
Word 3 Hi byte = ‘l’
Word 3 Lo byte = ‘\0’
(other words = 0)
Code
Name
Descriptions