Comtrol ES7510-XT User Manual
Page 157
![background image](/manuals/672025/157/background.png)
RocketLinx ES7510-XT User Guide: 2000571
Rev. D
Power over Ethernet (CLI) - 157
Configuration Using the Command Line Interface (CLI)
PoE Schedule Weekday Hour
Enable Hour 1, 3, 5
and 10 to 23 on
Sunday
Switch> enable
Switch# config term
Switch(config)# interface fa1
Switch(config-if)# poe schedule
<0-6> Weekday: valid range 0-6 (0=Sun, 1=Mon..., 6=Sat)
Switch(config-if)# poe schedule 0 1,3,5,10-23
Disable Sunday
Schedule
Switch(config-if)# no poe schedule 0
PoE Budget DC1/DC2
Set
Switch(config)# poe
disable Disables power over ethernet
enable Enables power over ethernet
budget Configure the power budget of power over ethernet
pd-detect Configure PD status detection
Switch(config)# poe budget
DC1 Power source : DC 1
DC2 Power source : DC 2
managed Manage the power budget function of power source is
unmanaged Unmanage the power budget function of power source
vin Input voltage
warning Warning water level
Switch(config)# poe budget DC1 120
PoE PD Detect
Enable
Switch> enable
Switch# config term
Switch(config)# poe
disable Disables power over ethernet
enable Enables power over ethernet
budget Configure the power budget of power over ethernet
pd-detect Configure PD status detection
Switch(config)# poe pd-detect
disable Disable PD status detection
enable Enable PD status detection
A.B.C.D PD IP address
Switch(config)# poe pd-detect enable
Disable
Switch(config)# poe pd_detect disable
PoE PD Detect Cycle Time
Ping 20 Sec, Re-
enable PoE
Switch(config)# poe pd_detect 192.160.1.2 20