2 recommended spare parts (cont'd), 3 parts service life, 3 parts service life -5 – Toshiba Q-Flowsaver II User Manual
Page 68: Toshiba, Service life replacement chart
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

TOSHIBA
12.2 Recommended Spare Parts (cont'd)
RANK
C
C
A
C
c
c
C
C
C
C
INVERTER
PCB
PCB 4-4B
PCB 5-5E
HCT
HCT
LI
FAN FOR
FAN FOR
MS1
MSX
UNIT
KEYPAD
SNUBBER
G-E
DC BUS
OUTPUT
DC
HEATSINK
CABINET
CONTACTOR
RELAY
CIRCUIT
REACTOR
QTY1
NOT
NOT
QTY1
NOT
QTY1
QTY2
NOT
QTY1
QTY1
Q2-4330
USED
USED
HC-S100M4P15E
USED
0.5mH
USED
35751B
45mV/1 OOA
55 A
129XR0281
C35A
JCIa-lOA
QTY1
NOT
NOT
NOT
QTY1
QTY1
QTY2
QTY1
QTY1
QTY1
Q2-4400
USED
USED
USED
NNC-20CAW(AMO)
0.4 mH
35751B
4V/68A
75 A
129XR0281
113XN0181
C35A
JCIa-lOA
QTY1
NOT
NOT
NOT
QTY1
QTY1
QTY2
QTY1
QTY1
QTY1
Q2-4500
USED
USED
USED
NNC-20CTW(AMO)
0.3 mH
35751B
4V/82A
88 A
129XR0281
113XN0181
C50A
JCIa-lOA
QTY1
QTY3
QTY6
NOT
QTY1
QTY1
QTY2
NOT
QTY1
QTY1
Q2-4600
USED
NNC-20CAW(AMO)
0.2 mH
USED
35751B
33251A
34557A
4V/1 OOA
114A
148VK0281
C50A
JCIa-lOA
QTY1
QTY3
QTY6
NOT
QTY2
QTY1
QTY2
QTY2
QTY1
QTY1
Q2-4800
USED
NNC-20CA(AMO)
0.2 mH
35751B
33251A
34557A
4V/130A
141 A
148VK0281
113XN0181
C65A
JCIa-lOA
QTY1
QTY3
QTY6
NOT
QTY2
QTY1
QTY2
QTY2
QTY1
QTY1
Q2-410K
USED
NNC-20CA(AMO)
0.15 mH
35751B
33251A
34557D
4V/160A
175 A
148VK0281
113XN0181
C80A
JCIa-lOA
QTY1
QTY3
QTY6
NOT
QTY1
QTY1
QTY2
QTY2
QTY1
QTY1
Q2-412K
USED
NNC-20CA(AMO)
0.23 mH
35751B
332510
34557D
4V/212A
220 A
148VK0281
113XN0181
C80A
JCIa-lOA
QTY1
QTY3
QTY6
QTY1
QTY2
NOT
QTY1
QTY1
QTY1
QTY1
Q2-415K
HEC-IOOA(AMO)
HEC-IOOA(AMO)
USED
McLean
38552B
344650
40651A
4V/230A
4V/230A
4B1212-230
148VK0281
C125A-E-A
JCIa-lOA
QTY1
QTY3
QTY6
QTY1
QTY2
NOT
QTY1
QTY1
QTY1
QTY1
Q2-420K
HEC-IOOA(AMO)
HEC-IOOA(AMO)
USED
McLean
38552B
344650
40651A
4V/300A
4V/300A
4B1212-230
148VK0281
C180A-E-A
JCIa-lOA
Notes:
Rank A signifies parts of relatively highest neoessity.
Rank C signifies parts of relatively lowest neoessity.
12.3 Parts Service Life
In order to obtain the best performance and to get the maximum service life from the
inverter it is necessary to perform timely maintenance repairs on some parts of the
system even though the equipment may still be functioning with no apparent problems
Use the following service life chart as a guide for major part periodic replacement when
the equipment is used in a standard installation service environment.
Service Life Replacement Chart
Part Name
Service Life
Remarks
Large capacity
electrolytic capacitor
5 Years
To be electrified semiannually in
case of long term disuse.
Cooling Fan
3 Years
Contact relays
500,000 operations
Connectors
100 operations
Replace pin in case of failure.
1 2 - 5