0 standard specifications (cont'd), Toshiba – Toshiba Q-Flowsaver II User Manual
Page 14
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

TOSHIBA
3.0
Standard Specifications (cont'd)
ITEM
STANDARD SPECIFICATIONS
Display
(4) 7-segment red LED
digits with colon and
decimal points
Output
frequency/
OFF
Frequency range 0.0 to 160 Hz and OFF state
(4) discrete green LED's
Warning
indications
Stall preventive warning, overvoltage limit
warning, overload warning, power-end undervoltage
warning, DC main circuit undervoltage warning,
setting errors, EEPROM abnormality, and data
transfer abnormality warnings
Fault
indications
Overcurrent, overvoltage, load-end ground fault,
overload, armature overcurrent at start-up, load-end
overcurrent at start-up, heat sink overheat.
Data and
status
Inverter status (forward/reverse run, frequency set
value, output current, etc.) and each set value
Speed
scaling
An arbitrary unit (revolution speed, linear velocity or
the like) as well as output frequency can be displayed
by use of an arbitrary multiplication factor
Data
storage
A number is assigned to each inverter (for 0 to 31
inverters).
(1) discrete red LED
(located inside enclosure)
DC charge
indicator
Main DC bus circuit capacitors charge indicator
Output signals
Fault detection signal
One form C contact (250 AC / 30 Vdc)
Low speed/reach signals
Open collector output (24 Vdc, 50 mA maximum)
Upper limit/lower limit
frequency signals
Open collector output (24 Vdc, 50 mA maximum)
Frequency meter output
and ammeter output
Ammeter rated at 1 mAdc at full scale, or voltmeter rated at
7.5 Vdc, 1 mA
Enclosure type
NEMAType 1 (standard)
Cooling method
Convection-cooled 02-2035 and 02-4055
Fan-cooled 02-2055 thru 02-2330 and 02-4080 thru Q2-420K
Color
Sherwin Williams Precision Tan #F63H12
Service
conditions
Service environment
Indoor, altitude 1000m (3,300 ft) maximum. Must not be exposed
to direct sunlight, or subjected to corrosive or explosive gas
or mists.
Ambient temperature
From -10 to 40°C (contact Toshiba about operation above 40°C)
Relative humidity
95 % maximum (no condensation allowed)
Vibration
Acceleration at 0.5 G maximum (20 to 50 Hz), amplitude at
0.1 mm maximum (50 to 100 Hz)
3 - 3