CHAPTER 2: TECHNICAL FEATURES AND DIMENSIONS

2.1 Modulex EXT Technical Features

Compact, gas fired, Low NO

x

, condensing boiler.

Comprised of one sectional boiler body, suitable as a single boiler or in a cascaded group.

May be installed in either an inside or outside location.

Low internal water volume.

Fast response to load variations.

Flue exhaust outlet positionable on three sides.

Manifold delivery and return.

Made up of four or more heating elements (4 to 8), cast aluminum / silicon / magnesium.

Full range of modulation by variable speed blowers and premix burners.

Each heating element monitors its own water temperature, and will individually shutdown

if flow is interrupted, without affecting the other burner sections.

One gas supply line.

Individual modules capable of between 83 and 382.5 kBTU/hr.

These boilers are designed for use with category IV venting.
The boiler is supplied complete with all the safety and control devices in accordance with all

current regulations, and its technical and functional features comply with the regulations

prescribed by:

ANSI Z21.13 / CSA 4.9 - Gas-fired low pressure steam and hot water boilers.

2.1.1 Temperature Control Devices:

Local NTC sensor (each heating

element)

Limit thermostat (each heating

element)

Flow NTC sensor (General)

Return NTC sensor (General)

Safety thermostat approved (manual

reset)

Flow sensor BCM

2.1.2 Control Panel (E8) Includes:

ON-OFF switch

Temperature control / Boiler operation

Fuses

High limit sensors

Air pressure fans

Condensate level sensor

Air pressure switch (anti-obstruction)

2.1.3 Other Features Include:

NTC heat sensors for global temperature control on the flow and return.

0-10 V output to control variable speed primary pump

Integral insulation with hypoallergenic synthetic wool.

Premix fiber mesh modulating burner (premixes into the fan with automatic diaphragm

backflow separation from the combustion chamber).

Less than 49 dBA of noise at maximum power.

Heating operation: instantaneous power microprocessor control, with preset parameters for