Disassembling the Boiler for Maintenance – Continued
6. Remove the rubber hoses (quantity depends on model) from bottom side of manifold
(highlighted in Figure 7-10), then lift entire manifold from the unit.
Figure 7-10: Removing Red Hoses and Manifold from Unit (Step 6)
7. Burner maintenance may be performed on all burner modules simultaneously or on each
one separately, as described in a) and b) below:
a)
All Modules: Use a 13mm wrench to remove all “A” and “C” nuts (surrounded by
horizontal dotted lines in Figure 7-11, below). Leave the “
B” screws affixed so all
burner plates may be lifted together. Then complete the remainder of the instructions
in this section.
b)
Separate Modules: Use a 13mm wrench to remove only the “A” and “C” nuts on
either side of the module in question (vertical dotted lines in figure 7-12), then
remove the “
B” Phillips screw at the end of the burner module. You can then skip the
remaining steps in this section and continue with section 11 - Cleaning the Burner
Module and Combustion Chamber.
Air Intake
Manifold
Remove
Hoses from under
Manifold
(one per module)
Lift out manifold after removing hoses.