Inter character delay, Inter character delay -6 – KEYENCE BL-N70 Series User Manual
Page 26

3-3 Data Send Format
3-6
3
Scannin
g Barcod
es
3 Read data
These digits contain the read barcode data.
4 Terminator
A character can be added to indicate the end of data.
• This parameter can be set to [CR], [CR][LF], [TAB], or [ETX].
Inter character delay
The time between each character can be set to three levels for the data sent from the BL-N70
series to the computer (
If the processing speed on the computer is slow, set a longer value for the inter character
delay. If the delay is not set long enough, the computer processing speed may fall behind
and digits may be dropped from the data. Adjust the inter character delay so that data is
received correctly from the reader.
UPC/EAN
UPC/EAN 13 digits
]E0
UPC/EAN 8 digits
]E4
UPC-A 13 digit format
]E0
UPC-A 12 digit format
UPC-E
]X0
CODE128
No FNC1
]C0
Has EAN-128
]C1
Second digit of data is FNC1
]C2
CODE93
–
]G0
GS1 Databar
–
]e0
Note
“None” is not an option. There must be a terminator.
Symbology
Data specifications
Symbology identifier