2 specifications, Specifications -3, Specifications – KEYENCE SJ-F100W/100/010 User Manual
Page 39: Static elimination blower unit/controller unit, Ac adapter
5-3
Spe
cif
ic
at
ion
s
5
5-2
Specifications
This section provides the specifications of the SJ-F100W/100/010.
Static Elimination Blower Unit/Controller Unit
* Values obtained by measurement 200 mm from the front of the Static Elimination Blower Unit
AC Adapter
Model
Static Elimination Blower Unit
SJ-F010
Controller Unit
SJ-F100W/100
Voltage application method
Variable DC
Applied voltage
±7000 V max.
Ion balance control method
I.C.C. method
Static elimination time*
1.8 sec
Ion balance*
±5 V
Max. fan speed*
1.5 m/s
Max. blast
1 m
3
/min
Ozone concentration
0.005 ppm max.
Control input
Static elimination stop input
NPN open collector or no-voltage contact signal
Control output
Alarm output
NPN open collector
100 mA (40 V max.)
Ion level alarm output
Condition alarm output
Rating
Power voltage
24 VDC ±10%
Current consumption
450 mA max.
Environmental
resistance
Operating ambient temperature
0 to +50°C
Operating ambient humidity
35 to 65%RH (condensation not allowed)
Weight
Static Elimination Blower Unit
Approx. 350 g
Controller Unit
Approx. 250 g
Model
SJ-U2
Rating
Rated input
100 to 240 VAC (50/60 Hz)
Rated output
24 VDC 2.65 A
Environmental
resistance
Operating ambient temperature
0 to +35°C
Operating ambient humidity
20 to 80% (condensation not allowed)
Weight
Approx. 250 g