5-3

Spe

cif
ic

at

ion
s

5

5-2

Specifications

This section provides the specifications of the SJ-F100W/100/010.

„ Static Elimination Blower Unit/Controller Unit

* Values obtained by measurement 200 mm from the front of the Static Elimination Blower Unit

„ AC Adapter

Model

Static Elimination Blower Unit

SJ-F010

Controller Unit

SJ-F100W/100

Voltage application method

Variable DC

Applied voltage

±7000 V max.

Ion balance control method

I.C.C. method

Static elimination time*

1.8 sec

Ion balance*

±5 V

Max. fan speed*

1.5 m/s

Max. blast

1 m

3

/min

Ozone concentration

0.005 ppm max.

Control input

Static elimination stop input

NPN open collector or no-voltage contact signal

Control output

Alarm output

NPN open collector
100 mA (40 V max.)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental
resistance

Operating ambient temperature

0 to +50°C

Operating ambient humidity

35 to 65%RH (condensation not allowed)

Weight

Static Elimination Blower Unit

Approx. 350 g

Controller Unit

Approx. 250 g

Model

SJ-U2

Rating

Rated input

100 to 240 VAC (50/60 Hz)

Rated output

24 VDC 2.65 A

Environmental
resistance

Operating ambient temperature

0 to +35°C

Operating ambient humidity

20 to 80% (condensation not allowed)

Weight

Approx. 250 g