2 Screen Functions and Operation

(3) Basic Point

If several peaks exist when using the transparent object mode, this control specifies

whether to use the peak that is NEAR or FAR from the sensor head as the reference.

(4) ABLE

ABLE sets whether to use AUTO or MANUAL control of the light intensity.

• Normally set to "AUTO".

• If set to "MANUAL", set the upper and lower limits for the light intensity control range

(setting range: 1 to 99).

(5) ABLE TUNING

This function uses "ABLE" to calibrate the "MANUAL" setting range according to the actual

object. Refer to "Performing the ABLE calibration" (Page 2-6) for details.

(6) Reflection type

Sets the reflection type to diffuse or mirror.

(7) Copy/Paste

Use these buttons to copy head settings to another head (or a head in a different program

number). Refer to "Copying the head settings to another head" (Page 2-5) for details.

Copying the head settings to another head

This example shows how to copy the settings for HEAD01 to HEAD02.

1

Complete all settings for HEAD01.

2

Touch "Copy".

"Paste" becomes active.

3

Touch "Head".

The "Select head" dialog box appears.

4

Touch "HEAD02".

5

Touch "Paste".

The settings for HEAD01 are copied to HEAD02.