USER SELECTION GUIDE (ACTIONMASTER SPECIFICATIONS)

230V Class (0.5~5.4HP)

Inverter Type

(SVxxxACtionMaster -x)

004-1

008-1

015-1

004-2

008-2

015-2

022-2

037-2

040-2

HP

0.5 1 2 0.5 1 2 3 5 5.4

Motor
Rating

1

kW

0.37 0.75 1.5 0.37 0.75 1.5 2.2 3.7 4.0

Capacity

2

[kVA]

1.1 1.9 3.0 1.1 1.9 3.0 4.5 6.1 6.5

FLA

[A]

3 5 8 3 5 8 12 16 17

Frequency

0.1 ~ 400 Hz

Output
Ratings

Voltage

200 ~ 230 V

3

Voltage

1 Phase
200 ~ 230 V (

± 10 %)

3 Phase
200 ~ 230 V (

± 10 %)

Input
Ratings

Frequency

50 ~ 60 Hz (

±5 %)

Braking Circuit

On Board

Average Braking Torque

20 % (Optional External DB Resistor: 100%, 150%)

Max. Continuous Baking
Time

15 seconds

Dynamic
Braking

Duty

0 ~ 30 % ED

Weight

[lbs]

2.65 3.97 4.63 2.65 2.65 3.97 4.63 4.85 4.85

460V Class (0.5~ 5.4HP)

Inverter Type

(SVxxxACtionMaster -x)

004-4

008-4

015-4

022-4

037-4

040-4

HP

0.5 1 2 3 5 5.4

Motor
Rating

1

kW 0.37

0.75

1.5

2.2

3.7

4.0

Capacity

2

[kVA]

1.1 1.9 3.0 4.5 6.1 6.5

FLA [A]

1.5

2.5

4

6

8

9

Frequency

0.1 ~ 400 Hz

Output
Ratings

Voltage

380 ~ 460 V

3

Voltage

3 Phase, 380 ~ 460 V (

± 10 %)

Input
Ratings

Frequency

50 ~ 60 Hz (

±5 %)

Braking Circuit

On Board

Average Braking Torque

20 % (Optional External DB Resistor: 100%, 150%)

Max. Continuous Braking
Time

15 seconds

Dynamic
Braking

Duty

0 ~ 30 % ED

Weight

[lbs]

3.75 3.75 3.97 4.63 4.85 4.85

1

Indicates the maximum applicable capacity when using a 4 pole motor.

2

Rated capacity (

√ 3*V*I) is based on 220V for 200V class and 440V for 400V class.

3

Maximum output voltage will not be greater than input voltage. Output voltage less than input voltage may be programmed.