Chapter 7 - options, 1 braking resistor – Cleveland Range inverter User Manual
Page 106

100
CHAPTER 7 - OPTIONS
7.1 Braking Resistor
Braking resistor is optional.
7.1.1 Lower Braking Magnitude
Model Number
SvxxxACtionMaster -x
004-1/2 008-1/2 015-1/2 022-2
037-2
040-2
004-4 008-4 015-4 022-4
037-4
040-4
Enable
Duty
[%]
5 5 3 2 2 5 5 3 2 2
Duty
Continuous Braking
Time [Sec]
5 5 5 5 5 5 5 5 5 5
Resistor Value [
Ω] 400 200 100 60 40 1800
900
450
300
200
Resistor
Resistor Capacity [W]
100
100
100
100
100
100
100
100
100
100
7.1.2 Higher
Braking
Magnitude
[200V Class]
Model Number
SvxxxACtionMaster -x
004-1/2
008-1/2
015-2/1
022-2
037-2
040-2
Average
Braking
Torque
[%] 100 150 100 150 100 150 100 150 100 150
Enable
Duty
[%]
5 5 5 5 5 5 5 5 5 5
Duty
Continuous Braking
Time [Sec]
5 5 5 5 5 5 5 5 5 5
Resistor Value [
Ω] 400 300 200 150 100 60 60 50 40 33
Resistor
Resistor
Capacity
[W] 100 150 100 150 200 300 300 400 600 600
[400V Class]
Model Number
SvxxxACtionMaster -x
004-4
008-4
015-4
022-4
037-4
040-4
Average
Braking
Torque
[%] 100 150 100 150 100 150 100 150 100 150
Enable
Duty
[%]
5 5 5 5 5 5 5 5 5 5
Duty
Continuous Braking
Time [Sec]
5 5 5 5 5 5 5 5 5 5
Resistor Value [
Ω] 400 300 900 600 450 300 300 200 200 130
Resistor
Resistor
Capacity
[W] 100 150 100 150 200 300 300 400 500 600