beautypg.com

5 how to check power components – Cleveland Range inverter User Manual

Page 101

background image

Chapter 6 - Troubleshooting & Maintenance

95

6.5 How to Check Power Components

Before checking the power components, be sure to disconnect AC Input supply and wait until the Main
Electrolytic Capacitors (DCP-DCN) are discharged to safe voltage levels.














1) Disconnect the power input line (R, S, T) and the inverter output to the motor (U, V, W).
2) Verify whether the inverter terminal R, S, T, U, V, W, B1, B2 is shorted or open by changing the

polarity of the tester.

3) Verify capacitor has discharged before testing.
4) The tester should display several mega-ohms when open. The tester can display terminal is shorted

for a short time and then display several mega-ohms because of the electrolytic capacitor. The tester
should display 1

Ω ~ 10 Ω when terminal is shorted. If all measured values are about the same,

individual modules are OK.

4) Diode module and IGBT module checking points:

Test Polarity

Test Polarity

Elements

+ -

Measured

Value

Element

+ -

Measured

Value

R B1 Short

R DCN

Open

D1

B1 R Open

D4

DCN R Short

S B1 Short

S DCN

Open

D2

B1 S Open

D5

DCN S Short

T B1 Short

T DCN

Open

Diode

Module

D3

B1 T Open

D6

DCN T Short

U B1 Short

U DCN

Open

Tr1

B1 U Open

Tr4

DCN U Short

V B1 Short

V DCN

Open

Tr3

B1 V Open

Tr6

DCN V Short

W B1 Short

W DCN

Open

IGBT

Module

Tr5

B1 W Open

Tr2

DCN W Short

R

G

E

G

E

G

E

G

E

G

E

G

E

S

T

U
V
W

G

E

DCP

B1

DCN

Charge resistor

Contactor

+

Electrolytic
capacitors

B2

Current Sensing Resistor

D1 D2 D3

D4 D5 D6

TR1

TR3

TR5

TR4

TR6

TR2