beautypg.com

Cleveland Range inverter User Manual

Page 38

background image

Chapter 3 - Parameter List

32

Code

Description

Keypad

Display

Setting Range

Units

Factory

Default

Adj.

During

Run

Page

I/O-35 Acceleration Time 6

I 35

0.0 to 999.9 [sec]

0.1 30.0

[sec] Yes

I/O-36 Deceleration Time 6

I 36

0.0 to 999.9 [sec]

0.1 30.0

[sec] Yes

I/O-37 Acceleration Time 7

I 37

0.0 to 999.9 [sec]

0.1 20.0

[sec] Yes

I/O-38 Deceleration Time 7

I 38

0.0 to 999.9 [sec]

0.1 20.0

[sec] Yes

0 (Frequency)
1 (Current)
2 (Voltage)

I/O-40

FM (Frequency Meter) Output
Selection

I 40

3 (DC Link Vtg)

-

0

(Frequency)

Yes

I/O-41 FM Output Adjustment

I 41

10 to 200 [%]

1

100 [%]

Yes

68

I/O-42 Frequency Detection Level

I 42

0 to FU1-20

0.01 30.00

[Hz] Yes

I/O-43 Frequency Detection Bandwidth

I 43

0 to FU1-20

0.01 10.00

[Hz] Yes

69

0 (FDT-1)
1 (FDT-2)
2 (FDT-3)
3 (FDT-4)
4 (FDT-5)
5 (OL)
6 (IOL)
7 (Stall)
8 (OV)
9 (LV)
10 (OH)
11 (Lost Command)
12 (Run)
13 (Stop)
14 (Steady)
17 (Search)

I/O-44

Multi-function Output Define (MO)



15, 16, 18, 19

(-Reserved-)

I 44

20 (Ready)

-

12 (Run)

Yes 69

I/O-45

Fault Output Relay Setting
(30A, 30B, 30C)

I 45

000 – 111 (bit set)
Bit 0: LV
Bit 1: All Trip
Bit 2: Auto Retry

- 010

Yes

72

I/O-46 Inverter Number

I 46

1 to 32

1 1

Yes

0 (1200 bps)
1 (2400 bps)
2 (4800 bps)
3 (9600 bps)

I/O-47 Baud Rate

I 47

4 (19200 bps)

-

3 (9600 bps) Yes

72

0 (None)

I/O-48 Operating selection at Loss of Freq.

Reference

I 48

1 (Free Run)

-

0 (None)

Yes 73