Chapter 4 - Parameter Description [DRV]


37


This code display the motor speed in RPM during
the motor is running.
Use the following equation to scale the
mechanical speed using FU2-74 [Gain for Motor
Speed display] if you want to change the motor
speed display to rotation speed (r/min) or
mechanical speed (m/min).

Motor Speed = 120 * (F/P) * FU2-74

Where, F: output frequency and P: the number of motor poles


DRV-10: DC Link Voltage





This code displays the DC link voltage inside the
inverter.

DRV-11: User Display Selection





This code display the parameter selected in FU2-
73 [User Display]. There are 3 types of
parameters in FU2-73 (Voltage, Watt and Torque).

DRV-12: Fault Display





This code displays the current fault (trip) status of
the inverter. Use the [FUNC], [▲] and [▼] key to
check for fault content(s), output frequency,
output current, or whether the inverter was
accelerating, decelerating, or in constant speed at
the time the fault occurred. Press the [FUNC] key
to exit. The fault content will be stored in FU2-01

to FU2-05 when the [RESET] key is pressed.

[Fault Contents]

Keypad Display

Fault (Trip)

Display

Over-Current

OC

Over-Voltage

OV

Emergency Stop

(Not latched)

BX

Low-Voltage

LV

Overheat on Heat Sink

OH

Electronic Thermal Trip

ETH

Overload Trip

OLT

Inverter H/W Fault
- EEP Error
- FAN Lock

- CPU Error
- Ground Fault

- NTC Wire Trouble

HW

Output Phase Loss

OPO

Inverter Overload

IOLT

Input Phase Open

COL


Note: The inverter will not reset when H/W fault occurs.

Repair the fault before turning on the power.

Note: When multiple faults occur, only the highest-level fault

will be displayed.






DRV-13: Motor Direction Set





This code sets the motor direction.

Display Description

F

Run Forward Direction

r

Run Reverse Direction


Related Functions: FU2-01 to FU2-05 [Previous Fault History]

FU2-06 [Erase Fault History]

FU2-01 to FU2-05: Up to 5 faults are saved.

FU2-06: Erases faults saved in FU2-01 to FU2-05.