Chapter 4 - Parameter Description [FU2]

52


FU2-19 [Phase Loss Protection Select]

Setting Range

2

nd

bit 1

st

bit

FU2-19 Description

0 0 00

Phase loss protection does not work

0 1 01

Protect inverter from output phase loss

1 0 10

Protect inverter from input phase loss

1 1 11

Protect inverter from input and output

phase loss




FU2-20: Power ON Start Selection





If FUN-20 is set to ‘No’, restart the inverter by
cycling the FX or RX terminal to CM terminal after
power has been restored.
If FUN-20 is set to ‘Yes’, the inverter will restart
after power is restored. If the motor is rotating by
inertia at the time power is restored, the inverter
may trip. To avoid this trip, use ‘Speed Search’
function by setting FU2-22 to ‘1xxx’.











[Power ON Start: ‘No’]

















[Power ON Start: ‘Yes’]

Note: In case of using ‘Power ON Start’ to ‘Yes’, make sure to

utilize appropriate warning notices to minimize the potential for
injury or equipment damage.



FU2-21: Restart After Fault Reset





If FU2-21 is set to ‘Yes’, inverter will restart after
the RST (reset) terminal has been reset a fault.
If FU2-21 is set to ‘No’, restart the inverter by
cycling the FX or RX terminal to CM terminal after
the fault has been reset. If the motor is rotating by
inertia at the time power is restored, the inverter
may trip. To avoid this trip, use ‘Speed Search’
function by setting FU2-22 to ‘xx1x’.










[Reset restart: ‘No’]

Related Functions: FU2-22 to FU2-25 [Speed Search]

Input Power

Time

FX-CM

ON

Time

ON

No Effect

Start

Power On

Output Frequency

Time

Input Power

Time

FX-CM

ON

Time

Start

Power On

Output Frequency

Time

Output Frequency

Time

FX-CM

ON

Time

RST-CM

ON

Time

ON

No Effect

Start

Tripped

Related Functions: FU2-22 ~ FU2-25 [Speed Search]