2 trap configuration, Trap configuration – CANOGA PERKINS 9145E10G NID Software Version 1.0 User Manual
Page 36

9145E10G NID Software User’s Manual
System Configuration
Trap Configuration
24
3.2 Trap Configuration
Trap configuration defines how various alarms events are handled. Traps can be configured to be
logged, sent to the SNMP managers in the Trap Notification/Destination Table, or both logged
and sent for each event. Traps can also be set to Disabled.
Trap Config Item
Traps Affected
MIB Location
Master Trap Control All
User Port Link Traps linkUp (User Port)
ifmib.my
linkDown (User Port)
ifmib.my
Network Port Link
Traps
linkUp (Network Port)
ifmib.my
linkDown (Network Port)
ifmib.my
Remote Fault Traps cp9145E10GPortRemoteFaultReceived cp9145E10GStatus.my
cp9145E10GPortSendingRemoteFault
cp9145E10GStatus.my
cp9145E10GPortRemoteFaultCleared cp9145E10GStatus.my
Link Loss Forwarding
Traps
cp9145E10GPortLLFActivated
cp9145E10GStatus.my
Cold Start Traps coldStart
v2-mib.my
Authentication Traps cpAuthenticationFailure
cpMgmtStatus.my
Diagnostic Traps cpPortLoopbackOn
cpLoopback.my
cpPortLoopbackOff
cpLoopback.my
Entity Configuration
Traps
entConfigChange
EntityMib.my
Fan/Power/
Temperature Traps
cpMainBoardVoltageLevelsOK
cpStatus.my
cpMainBoardVoltageLevelsOutOfRange
cpStatus.my
cpDyingGasp
cpPowerSupply.my
cpPowerSupplyFailed
cpPowerSupply.my
cpPowerSupplyOverHighLimit
cpPowerSupply.my
cpPowerSupplyUnderLowLimit
cpPowerSupply.my
cpPowerSupplyOK
cpPowerSupply.my
cpFanOK
cpFanStatus.my
cpFanSlow
cpFanStatus.my
cpFanFailed
cpFanStatus.my
cpTemperatureOverHighThresholdAlarm
cpStatus.my
cpTemperatureHighThresholdAlarmCleared cpStatus.my
cpTemperatureWarningApproachingHigh-
Threshold
cpStatus.my