7.5 Slip/PPP Baud Rate
To change the VT100 baud rate, from the Utilities menu, type 4 and press
rate setting will be highlighted. Use
115200. Press
7.6 PING Generation
From the Utilities menu, type 6 and press
appears. On the PING Generation screen, type the number of the entry you wish to modify and
press
Figure 7-3. PING Generation screen
1. On the PING Generation screen, type 1 and press
existing Ping to Address and type in the desired address.
NOTE: A Test IP address must be entered on the Management IP Configura-
tion menu (see Figure 3-3) in order to have Test IP appear as a Ping
from Address selection.
2. On the PING Generation screen, type 1 and press
through Tst IP, Mgr IP, Aux IP, and Auto Selection. Type
NOTE: If Auto Selection is chosen, Test IP will be used to perform the ping
test. If a Test IP is not avialable, Aux IP will be used. If an Aux IP is
not available, then Manager IP will be used.
3. When finished setting up the PING Generation screen entries, type 7 and press
to start the PING test.
4. When the test is complete, press
Canoga Perkins Corp. Ethernet Network Interface Device 04-Jan-1970
Model 9145-4 V06.29 F117 02:59:35
-------------------------------PING GENERATION----------------------------------
1) Ping to Address
: 0.0.0.0
2) Ping from Address
: Mgr IP 172.16.142.120
3) Ping Count
: 5
4) Ping VLAN ID
: 0
5) Ping Payload Size (40 - 1954)
: 40
6) Ping DF Bit
: Set
7)
Start
Pinging
Select [1-7]:
:------------------------------------Messages------------------------------------