Waterworks R.W. Atlas Exposed Thermostatic Valve with Metal Lever Handles User Manual
Page 4
PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
RW ATLAS
Exposed Thermostatic Valve
INSTALLATION GUIDELINES
Page 4 of 4
8.10.2012
These guidelines have been prepared for the professional contractor to aid in the installation of:
RW ATLAS EXPOSED THERMOSTATIC VALVE WITH METAL WHEEL HANDLE (STYLE# RWXS01)
& METAL LEVER HANDLE (STYLE # RWXS10)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
SEE SERVICE PART DOCUMENT FOR PART ORDERING, AVAILABLE ON WATERWORKS.COM
Figure - 05
HANDLE ASSEMBLY
LIMIT STOP
ASSEMBLY
LIMIT STOP PIN
[SHOWN REMOVED]
INSPECT THE INSTALLATION:
27. Turn the limit stop clockwise then turn the water on
and confirm the limit stop is functioning properly by
turning it counter-clockwise at which point it should
stop.
28. Verify the temperature to be the maximum
temperature set in Step 24. If it is not the correct
temperature, repeat the calibration procedures in
Steps 22-26.
29. To get a hotter temperature, press and hold the limit
stop button, then rotate the limit stop until it stops.
It is NOT recommended to exceed a safety limit stop
of 110 degrees.
30. Re-attach the handle assembly to the limit stop.
¾ If further assistance is required, please contact
Product Support at 1-800-927-2120 (8am-6pm EST).
¾ See service part document for parts ordering,
available on WATERWORKS.COM.