beautypg.com

Waterworks R.W. Atlas Low Profile Three Hole Wall Mounted Lavatory Faucet with Metal Lever Handles User Manual

Installation guidelines

background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

RW ATLAS

Wall Mounted Lavatory Faucet

INSTALLATION GUIDELINES

Page 1 of 3


8.9.2012

These guidelines have been prepared for the professional contractor to aid in the installation of:
RW ATLAS WALL MOUNTED LAVATORY WITH METAL WHEEL HANDLES (STYLE# RWLS60) &
METAL LEVER HANDLES (STYLE # RWLS70)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
SEE SERVICE PART DOCUMENT FOR PART ORDERING, AVAILABLE ON WATERWORKS.COM

Metal Wheel Handles
Style No. RWLS60

Metal Lever Handles
Style No. RWLS70

SPECIFICATIONS:

Control Valve Rough-In Depth Maximum: 5 -1/4"
Control Valve Rough-In Depth Minimum: 3-1/4"
Drain Depth Maximum: 2-5/8"
Drain Depth Minimum: 3/8"
Drain Hole Diameter: 1-3/4"
Drain Style: Push Touch (Drain Included)
Fitting Hole Diameter: 1-3/8"
Handle Spread: 8" (NOT ADJUSTABLE)
Inlet Connection Size: 1/2"
Inlet Connection Type: Female NPT
Maximum Water Pressure: 80psi
Minimum Water Pressure: 20psi
Recommended Water Pressure: 45psi
Restricted Maximum Flow Rate: 2.2gpm

REQUIRED PLUMBING DETAILS:
Universal Lavatory Wall Mounted Rough (For RWVC60)

STYLE No. GULV27
CODE No. GUSV27

Universal Lavatory Wall Mounted Rough (For RWVC70)

STYLE No. GULV25
CODE No. GUSV25

IMPORTANT:

¾ To ensure this product is installed properly, you

must read and follow these guidelines.

¾ The owner/user of this product must keep this

information for future reference.

¾ The faucet must be onsite prior to rough-in and

allows the installer to visualize the installation and
match the 8" center spread.

¾ Be sure your installation conforms to federal state,

and local codes. In the State of Massachusetts, all
installations must comply with the rules and
regulations set forth within 248 CMR.

¾ This product must be installed by a professional

licensed contractor.

¾ Inspect this product to ensure you have all the parts

required for proper installation.

¾ Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface.

¾ DO NOT use putty on fittings.

ROUGH-IN:

¾ Rough-in Depth from center of inlets to surface of

finished wall is 3-1/4" Minimum and 5-1/4" Maximum.

¾ Rough-in Height: 3-3/4" minimum from center of

cartridge stem to surface of countertop to allow for
lever handle clearance in the open position.

¾ See Figure - 01 for steps 1-6

1.

Run 1/2" hot and cold supply lines. The spread
between supplies is 8" on center and is NOT
adjustable.

2. Pre-solder a 1/2" male NPT x 1/2" Sweat adapter

(not supplied) to a small piece of 1/2" copper pipe
prior to threading into the valve body.

3. Thread the adapters into the valve and attach to the

supplies using 1/2" couplings (not supplied).

4. Verify the supplies are secure, level, and at the

proper spread of 8" and at equal depths prior to
making final solder connections.

5. Install a 1/2" NPT nipple (not supplied) to

temporarily serve as a spout.

6. Verify the supplies and valve body are secure, then

turn on the supplies and check for leaks.

Table of contents