Security settings, Automatic host mac detection, Disable snmp – Rice Lake CW-90X Over/Under/Washdown Checkweigher - Lantronix MatchPort User Manual
Page 66: Snmp community name, Disable telnet setup, Disable tftp firmware update

Configuration via Serial Mode or Telnet Port
MatchPort b/g™ User Guide
66
For more information on bridging, see
Config Server Port Number: (30718) ? _
Automatic Host MAC Detection
When Automatic Host MAC Detection is disabled (set to “N”) for bridging mode, the
MAC address of the bridged host can be set. When enabled (set to “Y'”), the MAC
address of the bridged host is detected automatically.
Security Settings
Security settings can only be changed using the setup menu (Telnet or serial).
Caution:
We recommend setting security over a dedicated network or over
the serial setup, to prevent eavesdropping.
Note:
To prevent unauthorized access from the network, disable the Telnet
setup, port 77FE, and the web setup features.
Disable SNMP
For security purposes, disable SNMP (if required) on the MatchPort unit. The current
setting displays in parentheses.
Disable SNMP (N) ? _
SNMP Community Name
The SNMP Community Name is a required field for NMS to read or write to a device.
Enter a string of 1 to 13 characters.
SNMP Community Name (public): _
The default entry is public. The current value displays in parentheses.
Disable Telnet Setup
This setting defaults to the N (No) option. The Y (Yes) option disables access
to the setup menu via Telnet to port 9999.
Disable Telnet Setup (N) ? _
Disable TFTP Firmware Update
This setting defaults to the N (No) option. The Y (Yes) option disables TFTP for
network firmware upgrades.
Disable TFTP Firmware Update (N) : _
Automatic Host MAC Detection
Wired Host MAC <00:00:00:00:00:00> <00> _ _