I/f (interface) mode, Table 5-3. interface mode options, Table 5-4. common interface mode settings – Rice Lake CW-90X Over/Under/Washdown Checkweigher - Lantronix MatchPort User Manual
Page 45

Configuration via Serial Mode or Telnet Port
MatchPort b/g™ User Guide
45
The current value displays in parentheses. The baud rates of 460800 and 921000
require a “High” CPU setting.
Baudrate (9600) ? _
I/F (Interface) Mode
The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation. The
current value displays in parentheses.
I/F Mode (4C) ? _
The following table displays available I/F Mode options:
Note:
All bit positions in the table that are blank represent “don’t care” bits for
that particular option, which can be set to either a 0 or 1 value.
Table 5-3.
Interface Mode Options
I/F Mode Option
7 6
5
4
3
2
1
0
RS-232
(1)
0
0
RS-422/485 4-wire
0
1
RS-485 2-wire
1
1
7 Bit
1
0
8 Bit
1
1
No Parity
0
0
Even Parity
1
1
Odd Parity
0
1
1 stop bit
0
1
2 stop bits
(1)
1
1
(1) 2 stop bits are implemented by the software. This might influence performance.
The following table demonstrates some common I/F Mode settings:
Table 5-4. Common Interface Mode Settings
Common I/F Mode Setting
Binary
Hex
RS-232C, 8-bit, No Parity, 1 stop bit
0100 1100
4C
RS-232C, 7-bit, Even Parity, 1 stop bit
0111 1000
78
RS-485 2-wire, 8-bit, No Parity, 1 stop
bit
0100 1111
4F
RS-422, 8-bit, Odd Parity, 1 stop bit
0101 1101
5D