Figure 4-7. channel serial settings – Rice Lake CW-90X Over/Under/Washdown Checkweigher - Lantronix MatchPort User Manual
Page 26

Configuration Using Web-Manager
MatchPort b/g™ User Guide
26
Figure 4-7. Channel Serial Settings
2. In the available fields, enter the following information:
Channel 1
Disable Serial Port
Available on Channel 2 settings only. When selected, disables
communication through the serial port.
Port Settings
Protocol
Select the protocol type from the drop-down list for the
selected channel. RS-422/485 4-wire and RS-485 2-wire
options are available on the MatchPort-485 only.
Flow Control
Flow control manages data flow between devices in a network
to ensure it is processed efficiently. Too much data arriving
before a device is prepared to manage it causes lost or
retransmitted data.
Baud Rate
The unit and attached serial device, such as a modem, must
agree on a speed or baud rate to use for the serial connection.
Valid baud rates are 300, 600, 1200, 2400, 4800, 9600
(default), 19200, 38400, 57600, 115200, 230400, 460800, and
921000.
Data Bits
Indicates the number of bits in a transmitted data package.
Parity
Checks for the parity bit. The default is None.
Stop Bits
The stop bit follows the data and parity bits in serial