Disconnect all cables from your KXPA100 and place it upside down, resting on the heat sink fins, on your

work table.

All of the screws that you will remove are identical and interchangeable. Take care to

save all of them and the other hardware you remove to reassemble the amplifier.

Remove the four corner feet. Each foot is held in place with six screws, spacers and lock washers.

Remove three screws, spacers and lock washers on the side as shown in Figure 17 and slide the foot off of
the other three screws, spacers and lock washers at the end panel.

Figure 17. Removing the Feet.

Remove the six screws, lock washers and spacers to free from the front and rear panels as shown in Figure

18. That will free the front panel. Set it aside in a safe place. The rear panel will be held in place by the wires
and cables to the connectors as shown in Figure 19. Do not try to remove it. Let it hang by the wires.

Figure 18. Freeing the Front and Rear Panels.