Glass installation, Step 6) glass installation, Includes offset and center-set glazing) – EFCO 433 Series User Manual
Page 80

June 2012
PART NO. Y017
Page 80 of 90
Series 433 Triple Set Installation Instructions
SECTION IX: Glazing
(Includes Offset and Center-Set Glazing)
Step 6) Glass Installation
A) Make sure the glazing blocks are still in place in the D.L.O. as instructed in Figures
98 and 99.
- For the following steps use Figures 102 and 103 below.
B) Position the glass on the appropriate side of the framing without the removable
glass stop installed. Shift the glass into the deep pocket to begin glass installation.
C) Swing the opposite edge of the glass around to align with the glazing pocket.
D) Slide the glass into the shallow pocket and lower onto the setting blocks. Shift the
glass until there is equal glass bite on both edges of the D.L.O. Ensure that the
preinstalled gasket does not roll out of the gasket race when moving the glass unit into
place.
E) Snap on the removable glass stop and install the antiwalk blocks and glazing gasket.
Use the instructions on page 79 for gasket installation. See Figures 114 through 119 on
pages 86, 87 and 88 for installation of the snap-in glass stop and antiwalk blocks.
B
D
E
GLASS
B
D
GLASS
[FIG. 101]
[FIG. 102]
NOTE:
This procedure works for all
captured glazing configurations
whether it is outside set
(shown), inside set, or
center-set glazing and inside
(shown) or outside glazed.
C
[FIG. 102]
[FIG. 103]