Series 433 Triple Set Installation Instructions

SECTION IV: Unit Assembly






















Expansion mullions are required in elevations that are over 20’-25’ wide

and can be used with both screw spline and shear block systems.

Note: Clean off all
excess sealant after

assembly.

A. Screw Spline (Offset and Center-Set)

Center Glazed Assembly With Expansion Mullion

Inside Glazed

BUTTER THE ENDS OF ALL

HORIZONTALS WITH BUTYL TYPE

SEALANT AS SHOWN BY THE

SHADED AREAS PRIOR TO

ASSEMBLY OF THE UNITS.

EXTERIOR FACE

4 ½” Head,

Horizontal, &

Sill Similar

Note: Wax Type Lubricant may be
required @ Assembly Fasteners.