beautypg.com

Detex DTX-4300 User Manual

Page 70

background image

This feature is useful considering the product only has
two relays; you can assign these relays to any of these
functions. There are only a few things to keep in mind
when assigning the outputs.

Any virtual output can be assigned to any physical
output.

A virtual output can be assigned to multiple physi-
cal outputs.

A physical output can only have one virtual output
assigned to it.

To assign the outputs, use the following command:

10 # virtual output # physical output # **

The chart below shows the output options with the
corresponding value.

Virtual Outputs

Physical Outputs

1 = Lock

1 = Main Relay

2 = Alarm Shunt

2 = Aux Relay

3 = Propped Door 5 = Audio Alert #1
4 = Forced Door

6 = Audio Alert #2

For example, to assign the Forced Door Output to the
Aux Relay, enter the following command in Program
mode:

10 # 4 # 2 # **

After entering this command, the Forced Door Output
is still assigned to Audio Alert #1. If you do not want
the audio alert to sound for Forced Door, you MUST
disable Audio Alert #1. To disable an output, enter a
0 for the virtual output. To disable Audio Alert #1 enter
following command:

10 # 0 # 5 # **

NOTE

: The audio alerts use the local keypad sounder.

Audio Alert #1 is indicated by a ½ second on, ½ second
off beeping. Audio Alert #2 is indicated by a short beep
every two seconds.

Chapter 4: Programming

4.3 Programming Outputs

4-18

prox.pad plus Install/Program. Manual, PPP, D4b

Part No. 6105679, Rev. 1.1