Detex Electric Signal Switching User Manual
Es (electric signal)
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130 (830)629-2900 /1-800-729-3839 /FAX(830)620-6711
E-MAIL: [email protected] INTERNET: www.detex.com
101282 Feb 14, 2005
INSTALLATION INSTRUCTIONS FOR ADVANTEX/VALUE SERIES RIM ES PRODUCT
DETEX INS-101282
Switch is not affected.
Door Closed - Deadlocking actuator activates PushPad/LBM Switch. Authorized Access
Door Closed - Depressing the PushPad changes the state of the PushPad/LBM Switch.
Authorized Access Switch is not affected.
latchbolt begins to retract, the PushPad/LBM Switch is also activated.
Door Closed - Authorized Access Switch is activated by operating outside trim. As the
Page 1
1) PushPad/LBM (Latch Bolt Monitor) monitors the pushpad and the
PushPad/LBM Switch *Normally Open held closed (Door Secure)
2) Authorized (Auth) Access Switch is activated by operating outside trim.
ES (Electric Signal)
Advantex/Value Series product consists of two switches:
Authorized Access Switch
TERMINAL BLOCK
*
Red wire
Theory of Operation:
Jewelers (Small) Screwdriver
1 2 3 4 5 6
COMMON
CLOSED
OPEN
COMMON
OPEN
CLOSED
Tools Required
PushPad/LBM Switch
CUSTOMER WIRING
deadlocking actuator in the latchbolt.