Alarms, Identify alarm – Carrier Access 770-0015 AM User Manual
Page 234

C-8
IP Router - Release 1.8
Troubleshooting
Alarms
Alarms
Identify Alarm
Alarm indicators
l
Router LEDs - When an Alarm is triggered, the Router LED (labeled CRD)
will display a red indicator light, which will stay on until the Alarm is cleared
The following chart describes each LED, and it’s state, of the Router card.
LED
State
Description
CRD
Off
Loss of power
Green
No current alarms
Red
Alarm state active. See alarm log for cause
Red Flashing
Self-test or Boot in-process
Yellow Flashing
Card is saving data to flash RAM, do not
power down
10/100
Off
10 Mb Ethernet
Green
100 Mb Ethernet
LNK
Off
No Ethernet link
Green
Good Ethernet link
COL
Off
No current ethernet transmit collisions
Yellow
Ethernet collisions have occurred and have
not dropped to minimum level
Yellow Flashing
Ethernet collision occurring
TX
Off
No Ethernet transmit activity
Green
Ethernet transmit activity
RX
Off
No current Ethernet receive activity
Green
Current Ethernet receive activity