Chapter 3: Installation

Page 3-4

2H22-08R SmartSwitch 2208 User’s Guide

3.4.2

Rackmount Installation

Rackmount installations must be within reach of the network cabling and
meet the requirements listed below:

Locate the 2H22-08R within seven feet of an appropriately grounded
power source and an unrestricted surface area as shown in

Figure 3-1

that meets the power supply requirements listed in

Appendix A

.

Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at
the installation site with fluctuations of less than 10°C (18°F) per hour.

The 2H22-08R is shipped with a strain-relief bracket for cable
management. The rackmount kit contains the rackmount brackets and
mounting screws for installing it in a 19-inch rack.

Attaching the Strain-Relief Bracket

Use of the strain-relief bracket is optional, but recommended to reduce
cable damage and maintain an orderly environment. Attach the
strain-relief bracket to the front of the 2H22-08R as follows:

1.

Locate the strain-relief bracket and four 8-32 x 3/8-inch pan-head
screws in the rackmount kit.

2.

Attach the strain-relief bracket to the bottom of the 2H22-08R using
the four 8-32 x 3/8-inch pan-head screws (

Figure 3-2

).

WARNING

Before installing the 2H22-08R

into a rack, ensure that the rack

supports the device(s) without compromising the stability of the
rack. Otherwise, personal injury and/or equipment damage
may result.

!

CAUTION

Do not attempt to attach the strain-relief bracket with screws
other than the 8-32 x 3/8-inch screws included with the
2H22-08R. Use of longer screws may damage the unit.