Syslogdip, Tempshow, Syslogdip -31 – Dell PowerVault 51F (8P Fibre Channel Switch) User Manual
Page 93: Tempshow -31

support.dell.com
PowerVault 51F Commands
4-31
syslogdIp
The syslogdIp command sets or displays the switches system log daemon IP
address. The command syntax is
syslogdip <ip address>.
tempShow
The following example shows the tempShow command screen, which shows the
switch’s temperature as measured by five sensors on the system board.
Port state
The port state follows the GBIC type. The possible port states
include:
•
No_Card — No card present in this switch slot
•
No_Module — No GBIC module in this port
•
No_Light — The module is not receiving light
•
No_Sync — The module is receiving light but is out of
sync
•
In_Sync — The module is receiving light and is in sync
•
Laser_Flt — The module is signaling a laser fault (defec-
tive GBIC)
•
Port_Flt — The port has been marked faulty (defective
GBIC, cable, or device)
•
Diag_Flt — The port failed diagnostics (defective G_Port
or FL_Port card or system board)
•
Online — The port is up and running
•
Lock_Ref — The port locking to the reference signal
•
Testing — Running diagnostics
Comment field
The comment field follows the port state. The possible com-
ments include:
•
Disabled
—
The port is disabled
•
Loopback
—
The port is in loopback mode
•
E_Port
—
The WWN and switch name of the other
switch is shown, the use of this Inter Switch Link (ISL) is
shown (see FC_SW)
•
F_Port
—
The WWN of the N_Port is shown
•
G_Port
—
The port is online but is not yet an E_Port or
F_Port
•
L_Port
—
The port is connected to an arbitrated loop
Table 4-16. switchShow Command Field Descriptions (continued)
Field
Description