beautypg.com

Diaghelp, Errdisplayfilter, Errdump – Dell PowerVault 51F (8P Fibre Channel Switch) User Manual

Page 77: Diaghelp -15, Errdisplayfilter -15, Errdump -15, Routehelp -4

background image

support.dell.com

PowerVault 51F Commands

4-15

d.

MM

is the minutes

e.

yy

is the year

2.

Press to set the date and time.

NOTE: The date function does not support daylight savings time. The date must be
reset manually when the time changes.

diagHelp

The diagHelp command displays the diagnostic help commands available for trouble-
shooting switch problems. These commands should be run only as advised by Dell
technical support. The following example shows the information that appears when
the command is run

e

errDisplayFilter

The errDisplayFilter command allows you to specify the minimum error level to be
reported on the PowerVault 51F switch only. Error level values range from 1 to 5. The
following is example of the errDisplayFilter command:

Errors with a level of severity lower than 4 are displayed in the error log.

errDump

The errDump command prints the contents of the error log with no page breaks.

switch:admin> diagHelp

ramTest System DRAM diagnostic

portRegTest Port register diagnostic

centralMemoryTest Central memory diagnostic

cmiTest CMI bus connection diagnostic

camTest Quickloop CAM diagnostic

portLoopbackTest Port internal loopback diagnostic

sramRetentionTest SRAM Data Retention diagnostic

cmemRetentionTest Central Mem Data Retention diagostic

crossPortTest Cross-connected port diagnostic

spinSilk Cross-connected line-speed exerciser

diagClearError Clear diag error on specified port

diagDisablePost Disable Power-On-Self-Test

diagEnablePost Enable Power-On-Self-Test

setGbicMode Enable tests only on ports with GBICs

supportShow Print the switch info for debugging

diagShow Print diagnostic status information

switch:admin> errDisplayFilter

This manual is related to the following products: