diagHelp
The diagHelp command displays the diagnostic help commands available for trouble-
shooting switch problems. These commands should be run only as advised by Dell
technical support. The following example shows the information that appears when
the command is run
e
errDisplayFilter
The errDisplayFilter command allows you to specify the minimum error level to be
reported on the PowerVault 51F switch only. Error level values range from 1 to 5. The
following is example of the errDisplayFilter command:
Errors with a level of severity lower than 4 are displayed in the error log.
errDump
The errDump command prints the contents of the error log with no page breaks.
switch:admin> diagHelp
ramTest System DRAM diagnostic
portRegTest Port register diagnostic
centralMemoryTest Central memory diagnostic
cmiTest CMI bus connection diagnostic
camTest Quickloop CAM diagnostic
portLoopbackTest Port internal loopback diagnostic
sramRetentionTest SRAM Data Retention diagnostic
cmemRetentionTest Central Mem Data Retention diagostic
crossPortTest Cross-connected port diagnostic
spinSilk Cross-connected line-speed exerciser
diagClearError Clear diag error on specified port
diagDisablePost Disable Power-On-Self-Test
diagEnablePost Enable Power-On-Self-Test
setGbicMode Enable tests only on ports with GBICs
supportShow Print the switch info for debugging
diagShow Print diagnostic status information
switch:admin> errDisplayFilter