E122C

CPU Power

Fault. Power

cycle AC.

A power fault detected when
powering up the
processor(s).

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 195.

E122D

Memory

Regulator #

Failed.

Reseat DIMMs.

One of the memory
regulators failed.

Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 169.

If the problem persists,
see "Getting Help" on
page 195.

E122E

On-board

regulator

failed. Call

support.

One of the on-board voltage
regulators failed.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 195.

E1243

CPU # VCORE

Regulator

failure.

Contact

Support

Processor voltage regulator
failed.

Reseat the processor. See
"Troubleshooting the
Processors" on page 178.

If the problem persists,
see "Getting Help" on
page 195.

E1245

CPU # VIO

Regulator

failure.

Contact

support

Processor voltage regulator
failed.

Reseat the processor.
"Troubleshooting the
Processors" on page 178.

If the problem persists,
see "Getting Help" on
page 195.

E1310

Fan ## RPM

exceeding

range. Check

fan.

RPM of specified fan is
outside the intended
operating range.

See "Troubleshooting
System Cooling
Problems" on page 167.