beautypg.com

Dell PowerEdge R810 User Manual

Page 33

background image

About Your System

33

E1A12

PCI Riser not

detected.

Check Riser.

One or both of the PCIe
risers are missing. This
prevents the system from
powering on.

Reinstall the missing riser
card(s). See "Installing
Expansion-Card Riser 1"
on page 121 an
d
"Installing Expansion-
Card Riser 2" on page 122.

E1813

Internal Dual

SD Module

Card #

failed. Check

SD card

The internal dual SD
module card failed.

Reseat the internal dual
SD module card.

If the problem persists,
see "Getting Help" on
page 195.

E1814

Internal SD

Module Card #

write-

protected.

Check SD card

The internal dual SD
module card is write-
protected and cannot be
used.

Change the write-protect
switch setting on SD card.

E1815

Internal Dual

SD Module

redundancy

lost. Check

SD cards

The internal dual SD
module bootable media is
no longer redundant.

Reseat the internal dual
SD module card.

If the problem persists,
see "Getting Help" on
page 195.

E1A14

SAS cable A

failure.

Check

connection.

SAS cable A is missing or
bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 195.

E1A15

SAS cable B

failure.

Check

connection.

SAS cable B is missing or
bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 195

Code

Text

Causes

Corrective Actions

book.book Page 33 Thursday, February 18, 2010 2:06 PM