beautypg.com

Dell PowerEdge R810 User Manual

Page 34

background image

34

About Your System

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control
panel is missing or bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 195.

E2010

Memory not

detected.

Inspect

DIMMs.

No memory detected in the
system.

Install memory or reseat
the memory modules. See
"Installing Memory
Modules" on page 105 or
"Troubleshooting System
Memory" on page 169.

E2011

Memory

configuratio

n failure.

Check DIMMs.

Memory detected, but is not
configurable. Error detected
during memory
configuration.

See "Troubleshooting
System Memory" on
page 169.

E2012

Memory

configured

but unusable.

Check DIMMs.

Memory configured, but is
unusable.

See "Troubleshooting
System Memory" on
page 169.

E2013

BIOS unable

to shadow

memory. Check

DIMMs.

The system BIOS failed to
copy its flash image into
memory.

See "Troubleshooting
System Memory" on
page 169.

E2014

CMOS RAM

failure.

Power cycle

AC.

CMOS failure. CMOS RAM
not functioning properly.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 195.

E2015

DMA

Controller

failure.

Power cycle

AC.

DMA controller failure.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 195.

Code

Text

Causes

Corrective Actions

book.book Page 34 Thursday, February 18, 2010 2:06 PM