E2023
BIOS unable
to mirror
memory. Check
DIMMs.
The system BIOS could not
enable memory mirroring
because of a faulty memory
module or an invalid
memory configuration.
See "Troubleshooting
System Memory" on
page 169.
E2025
QPI
initializati
on error.
Contact
support
QuickPath Interconnect
(QPI) failure.
See "Getting Help" on
page 195.
E2026
Memory
initializati
on error.
Contact
support
Invalid memory
configuration.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines"
on page 100. See "Getting
Help" on page 195.
E2110
Multibit
Error on DIMM
##. Reseat
DIMM.
The memory module in slot
"##" has had a multi-bit
error (MBE).
Reseat the memory
module in its socket.
If the problem persists,
see "Troubleshooting
System Memory" on
page 169.
E2111
SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS disabled
memory single-bit error
(SBE) logging and will not
log any more SBEs until the
system is rebooted. "##"
represents the memory
module implicated by the
BIOS.
Reseat the memory
module in its socket.
If the problem persists,
see "Troubleshooting
System Memory" on
page 169.
Code
Text
Causes
Corrective Actions
book.book Page 37 Thursday, February 18, 2010 2:06 PM