beautypg.com

Dell PowerEdge R810 User Manual

Page 37

background image

About Your System

37

E2023

BIOS unable

to mirror

memory. Check

DIMMs.

The system BIOS could not
enable memory mirroring
because of a faulty memory
module or an invalid
memory configuration.

See "Troubleshooting
System Memory" on
page 169.

E2025

QPI

initializati

on error.

Contact

support

QuickPath Interconnect
(QPI) failure.

See "Getting Help" on
page 195.

E2026

Memory

initializati

on error.

Contact

support

Invalid memory
configuration.

Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines"
on page 100. See "Getting
Help" on page 195.

E2110

Multibit

Error on DIMM

##. Reseat

DIMM.

The memory module in slot
"##" has had a multi-bit
error (MBE).

Reseat the memory
module in its socket.

If the problem persists,
see "Troubleshooting
System Memory" on
page 169.

E2111

SBE log

disabled on

DIMM ##.

Reseat DIMM.

The system BIOS disabled
memory single-bit error
(SBE) logging and will not
log any more SBEs until the
system is rebooted. "##"
represents the memory
module implicated by the
BIOS.

Reseat the memory
module in its socket.

If the problem persists,
see "Troubleshooting
System Memory" on
page 169.

Code

Text

Causes

Corrective Actions

book.book Page 37 Thursday, February 18, 2010 2:06 PM