E1624

Lost power

supply

redundancy.

Check PSU

cables.

The power supply subsystem
is no longer redundant. If
the remaining power supply
fails, the system will shut
down.

See "Troubleshooting
Power Supplies" on
page 167.

E1626

Power Supply

Mismatch.

PSU1 = ### W,

PSU2 = ### W.

The power supplies in the
system are not of the same
wattage.

Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system’s Getting
Started Guide.

E1629

Power

required >

PSU wattage.

Check PSU and

config.

The system configuration
requires more power than
the power supplies can
provide, even with
throttling.

Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

E1631

System power

draw exceeded

threshold.

Contact

support.

The processors and memory
throttling is not sufficient to
keep system power
consumption below the
maximum safe level with
current power supply
configuration.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 195.

E1632

PowerSafe

event.

Contact

support.

The processors and memory
have been throttled to keep
system power consumption
below the maximum safe
level with current power
supply configuration.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 195.

Code

Text

Causes

Corrective Actions

book.book Page 29 Thursday, February 18, 2010 2:06 PM