beautypg.com

Dell PowerEdge R810 User Manual

Page 24

background image

24

About Your System

E1116

Memory

disabled,

temp above

range. Power

cycle AC.

Memory exceeded allowable
temperature and has been
disabled to prevent damage
to the components.

Remove AC power to the
system for 10 seconds and
restart the system.

See "Troubleshooting
System Cooling
Problems" on page 167. If
the problem persists, see
"Getting Help" on
page 195.

E1210

Motherboard

battery

failure.

Check

battery.

CMOS battery is missing or
the voltage is outside the
allowable range.

See "Troubleshooting the
System Battery" on
page 166.

E1211

RAID

Controller

battery

failure.

Check

battery.

RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.

Reseat the RAID battery
connector. See "Installing
the RAID Battery" on
page 130 and
"Troubleshooting System
Cooling Problems" on
page 167.

E1216

3.3V

Regulator

failure.

Reseat PCIe

cards.

3.3 V voltage regulator
failed.

Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 177.

E1222

CPU # VCACHE

Regulator

failure.

Contact

support.

Processor voltage regulator
failed.

Reseat the processor(s).
See "Troubleshooting the
Processors" on page 178.

If the problem persists,
see "Getting Help" on
page 195.

Code

Text

Causes

Corrective Actions

book.book Page 24 Thursday, February 18, 2010 2:06 PM