About Your System

E1313

Fan

redundancy

lost. Check

fans.

The system is no longer fan
redundant. Another fan
failure would put the system
at risk of over-heating.

Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan"
on page 168.

E1314

Critical

system

cooling loss.

Check fans

All fans have been removed
from the system.

Ensure that the fans are
properly installed. See
"Troubleshooting a Fan"
on page 168.

E1410

System Fatal

Error

detected.

A fatal system error
detected.

Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 195.

E1414

CPU # temp

exceeding

range. Check

CPU heat

sink.

Specified processor is out of
acceptable temperature
range.

Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processors" on page 178
and "Troubleshooting
System Cooling
Problems" on page 167.

E1418

CPU # not

detected.

Check CPU is

seated

properly.

Specified processor is
missing or bad, and the
system is in an unsupported
configuration.

Ensure that the specified
processor is properly
installed and is as per the
supported configuration.
See Table 3-5 and
"Troubleshooting the
Processors" on page 178.

Code

Text

Causes

Corrective Actions