Troubleshooting a damaged system, Troubleshooting the system battery, Troubleshooting the power supply – Dell PowerEdge 500SC User Manual
Page 32: Troubleshooting the cooling fan

5.
Replace the system cover, reconnect the system to the electrical outlet, and turn on the system.
If the system does not start up properly, see "
Getting Help
," for instructions on obtaining technical assistance.
6.
If the system starts up normally, shut down the system and reinstall all expansion cards you removed in step 3.
7.
Run the system board tests in the system diagnostics to confirm that the system is working properly.
If the tests did not complete successfully, see "
Getting Help
," for instructions on obtaining technical assistance.
Troubleshooting a Damaged System
Problem
l
System dropped or damaged
Action
1.
Check the expansion-card connections to the system board.
2.
Make sure that all cables are properly connected and that all components are properly seated in their connectors and sockets.
3.
Run the system board tests in the system diagnostics.
If the tests did not complete successfully, see "
Getting Help
," for instructions on obtaining technical assistance.
Troubleshooting the System Battery
Problem
l
Error message shows problem with the battery
l
System Setup program loses the system configuration information
l
System date and time will not stay current
Action
1.
Check the connection of the coin cell battery to the system board.
See "
Replacing the System Battery
" in "Installing System Board Options."
2.
If the problem is not resolved by reseating the battery, replace the battery.
If the problem is not resolved by replacing the battery, see "
Getting Help
," for instructions on obtaining technical assistance.
Troubleshooting the Power Supply
Problem
l
Green power indicator on the system bezel is not lit
l
Server management application program issues a power supply-related error message
Action
1.
Check the power outlet and power cable (see "
Checking Connections and Switches
" in "Indicators, Messages, and Codes").
2.
Turn off the system, including any attached peripherals, and disconnect all the power cables from the electrical outlets.
3.
Remove the system cover. See "
Replacing the System Cover and Support Beam
4.
Check the power cable connection to the POWER connector on the system board.
If the problem is not resolved, see "
Getting Help
," for instructions on obtaining technical assistance.
Troubleshooting the Cooling Fan
WARNING:
There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type
recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions.
CAUTION:
See "Protecting Against Electrostatic Discharge" in your System Information document.