Diskette drive 0 seek

failure

Faulty or improperly inserted diskette,
incorrect configuration settings in System
Setup program, loose diskette drive
interface cable.

Replace the diskette. Run the System Setup program to correct the diskette drive
type. See "Using the System Setup Program," in the User's Guide for instructions.
Check the interface cable and power cable connections to the system board. See
"

Installing Drives

."

Diskette drive 1 seek

failure

Diskette read failure

Faulty diskette, faulty or improperly
connected diskette drive.

Check the interface cable and power cable connections to the system board. See
"

Installing Drives

."

Diskette subsystem

reset failed

Faulty diskette controller (defective system
board).

Replace the system board. See "

Installing Drives

," for instructions on obtaining

technical assistance.

Diskette write

protected

Diskette write-protect feature activated.

Move the write-protect tab on the diskette.

Drive not ready

Diskette missing from or improperly
inserted in diskette drive.

Reinsert or replace the diskette.

Gate A20 failure

Faulty keyboard controller (defective
system board).

Replace the system board. See "

Getting Help

," for instructions on obtaining

technical assistance.

General failure

Operating system corrupted or not
installed properly.

Reinstall the operating system.

Hard disk controller

failure

Incorrect configuration settings in System
Setup program, improperly connected hard
drive, faulty hard drive controller
subsystem (defective system board), or
loose power cable.

Check the hard drive configuration settings in the System Setup program. See
"Using the System Setup Program," in the User's Guide for instructions. Reinstall the
hard drive. See "

Installing Drives

." Check the interface cable and power cable

connections to the system board. See "

Installing Drives

."

Hard disk drive read

failure

Hard disk failure

Invalid configuration

information - please

run SETUP program

Incorrect configuration settings in System
Setup program, faulty battery, or NVRAM
jumper is installed.

Check the System Setup configuration settings. See "Using the System Setup
Program," in the User's Guide for instructions. Replace the battery. See "

Replacing

the System Battery

" in "Installing System Board Options." Remove the NVRAM

jumper. See "

Figure A

-2

" for jumper location.

Invalid CPU speed

detected

Microprocessor not supported by system.

Install a correct version of the microprocessor in the specified microprocessor
connector. See "

Replacing the Microprocessor

" in "Installing System Board Options."

Invalid NVRAM

configuration, resource

reallocated

System detected and corrected a resource
conflict when system resources were
allocated using the System Setup program.

No action is required.

I/O parity interrupt at

address

Expansion card improperly installed or
faulty.

Reinstall the expansion cards. See "

Installing Expansion Cards

" in "Installing

System Board Options." If the problem persists, replace the expansion card. See
"

Removing Expansion Cards

" in "Installing System Board Options."

Keyboard failure

Keyboard cable connector loose or
improperly connected, defective keyboard,
or defective keyboard/mouse controller
(defective system board).

Check the keyboard cable connection. Replace the keyboard. If the problem
persists, replace the system board. See "

Getting Help

," for instructions on obtaining

technical assistance.

Keyboard data line

failure

Keyboard stuck key

failure

Keyboard clock line

failure

Keyboard controller

failure

Defective keyboard/mouse controller
(defective system board).

Replace the system board. See "

Getting Help

," for instructions on obtaining

technical assistance.

Memory address line

failure at address,

read value expecting

value

Faulty or improperly seated memory
modules or defective system board.

Remove and reseat the memory modules. See "

Adding Memory

" in "Installing

System Board Options." If the problem persists, replace the memory modules. See
"

Adding Memory

" in "Installing System Board Options." If the problem persists, see

"

Getting Help

," for instructions on obtaining technical assistance.

Memory data line

failure at address,

read value expecting

value

Memory double word

logic failure at

address, read value

expecting value

Memory odd/even logic

failure at address,

read value expecting

value

Memory write/read

failure at address,

read value expecting

value

Memory allocation error

Faulty application program.

Restart the application program.

Memory parity interrupt

at address

Improperly seated or faulty memory
modules.

Remove and reseat the memory modules. See "

Adding Memory

" in "Installing

System Board Options." If the problem persists, replace the memory modules. See
"

Adding Memory

" in "Installing System Board Options." If the problem persists, see

"

Getting Help

," for instructions on obtaining technical assistance.

Memory tests terminated

by keystroke

POST memory test terminated by pressing
the spacebar.

No action is required.

No boot device

available

Faulty diskette, diskette subsystem, hard
drive, hard drive subsystem, or no boot
disk in drive A.

Replace the diskette or hard drive. See "

Installing Drives

." If the problem persists,

replace the system board. See "

Getting Help

," for instructions on obtaining technical

assistance.

No boot sector on hard

drive

Incorrect configuration settings in System
Setup program, or no operating system on
hard drive.

Check the hard drive configuration settings in the System Setup program. See
"Using the System Setup Program," in the User's Guide for instructions.