Show storage array power information, Show storage array unconfigured iscsi initiators, Show storage array unreadable sectors – Dell PowerVault MD3420 User Manual
Page 358

Show Storage Array Power Information
Description
This command returns information about the amount of power consumed by the entire storage array and
each enclosure in the storage array.
Syntax
show storageArray powerInfo
Parameters
None
Notes
This command returns power consumption information similar to this example.
total power drawn: 310 watts
number of enclosures: 1
enclosure power input details:
enclosure id power supply serial number input power
0 0 160 watts
0 1 150 watts
Show Storage Array Unconfigured iSCSI Initiators
Description
This command returns a list of initiators that have been detected by the storage array but are not yet
configured into the storage array topology.
Syntax
show storageArray unconfiguredIscsiInitiators
Parameters
None.
Show Storage Array Unreadable Sectors
Description
This command returns a table of the addresses of all of the sectors in the storage array that cannot be
read. The table is organized with column headings for the following information:
• Virtual disk user label
• Logical unit number (LUN)
358