86 |
Operating variables |
H5000 Operation Manual
Analog
There are four analog channels built into the CPU and multiple analog modules can be added
to the network.
Once a device is wired into an analog channel it must be confi gured before it will provide the
correct data.
Calibration of analog (linear) functions
For all linear functions it is necessary to set the Type value (see table below).
Description
Function declared
0 to 10 Linear
None
0 to 100 Linear
None
0 to 1000 Linear
None
x2
y1
y2
x1
x1
=
Analog Volts 1
y1
=
Analog value 1
x2
=
Analog Volts 2
y2
=
Analog value 2
¼
Note:
Analog linear channel is the channel on the display where the data is sent to. There are
user channels available.