beautypg.com

Temperature - sea, Tide set and rate, Timer – B&G H5000 Analogue Expansion User Manual

Page 104

background image

104 |

Operating variables |

H5000 Operation Manual

Temperature - Sea

Displays the current water temperature.

Variable name (default)

Function name

Sea Temperature (Sea)

SEA TEMP

Units

ºC, ºF

Alarms

High and Low

Calibration

Off set

Damping

N/A

Tide set and rate

The system calculates current fl ow by comparing the Boat Speed and Course (which are
measured relative to the water) to the ground referenced data (SOG and COG) from a GPS.
This calculation therefore includes all water motion including both tides and permanent
currents.

As the calculation utilizes the Course function its accuracy can be enhanced by the use of a
Heel Angle sensor and accurate Leeway calibration.

¼

Note:

If your position fi xer sends magnetic bearing, check that the variation is correctly

entered (or calculated) in the position fi xer.

Importantly the damping on this function is adjustable, in rapidly changing tidal situations
you need to lower the damping down as far as possible to be able to see the changes quickly.
However in stable conditions, probably off shore, averaging the data over a longer time will
normally give a more stable, accurate fi gure. In addition note that particularly frequent
manoeuvring can produce unreliable fi gures due to the lag in update from position fi xing
devices.

Variable name (default)

Function name

Tide Set (T SET), Tide Rate (T RTE)

TIDE SET, TIDE RTE

Units

ºM, ºT, nm

Alarms

N/A

Calibration

Magnetic Variation

Damping

0-9s

Timer

The system Timer can be used for either countdown or as a straight-forward stopwatch.

¼

Note:

If your position fi xer sends magnetic bearing, check that the variation is correctly

entered (or calculated) in the position fi xer.

Variable name (default)

Function name

Timer

TIMER

Units

hh:mm:ss

Alarms

Countdown bleep via Audible Alarm

Calibration

Set countdown period

Damping

N/A