beautypg.com

Appendix c: battery life, Power supply options – ADS Environmental Services XiLog+ QR 775026 A0 User Manual

Page 75

background image

ADS XiLog+ System User Manual

69

Appendix C: Battery Life

Measurement

Interval

Transmission

Standard

Internal

Battery

Double

Internal

Battery

External

Lithium

Battery

≥1 minute

Once per day

>5 years

>10 years

≥1 minute

Once per hour

>1.2 years

>2.5 years

>7 years

≥1 minute

Once every 15
minutes (for 10
hours a day)

>0.7 year

>1.5 years

>5 years

≥1 minute

Once every 15
minutes

0.3 year

0.7 year

2.5 years

Power Supply Options

Following are the internal power options available for the XiLog+:

Standard pack

Double battery pack

Following are the external power options available for the XiLog+ (all
loggers
):

External battery pack

Mains

Solar