Installation, Commissioning mode – ADS Environmental Services XiLog+ QR 775026 A0 User Manual
Page 34

ADS XiLog+ System User Manual
28
Installation
Installation window
This window includes all the parameters relevant to installing the logger at the
site.
Commissioning Mode
This drop-down list contains the options available for communication:
Commissioning Mode menu options
On
Selecting this option places the logger in commissioning mode. This mode
ensures the logger remains powered up, connected to the GSM network, and
available for communication.
Note: Do not maintain a logger in commissioning mode for a long
period of time. This will have a detrimental effect on battery life.
Note: Leaving a logger in commissioning mode will generate and
send an SMS alarm at 00:00 every day until this mode is discontinued.
Discontinue this mode by sending the string #CMOFF to the logger
from a cellular phone.
Off
Selecting this option powers up the modem only as designated under the
current setup. This is the standard operating mode.