Page 56: Data transmission, Daily data transmission

ADS XiLog+ System User Manual
50
FTP Password
This field represents the password for logging onto the FTP server. Enter the
appropriate password for the user.
Test Login Details
Clicking on this button verifies the FTP server address, username, and
password by attempting to call and log into the server. PrimeWorks will
provide notification of success or failure. A failure may indicate the wrong
server address or login information.
Combine Flow and Pressure
When using a 2i or 3i version of the XiLog+ and sending data via SMS, the
flow and pressure data can be included in a single SMS. For this to occur, set
up the system to log pressure at a 15-minute interval and flow at a 15-minute
interval.
Designating these criteria enables the Combine Flow and Pressure checkbox
for selection. Selecting this checkbox sends a single SMS (instead of two)
representing both channels each day.
Data Transmission
Data Transmission sub-window
This window contains the parameters for setting up the process the XiLog+
uses for transmitting logged data.
Daily Data Transmission
Selecting the Transmit Daily checkbox programs the logger to send the data
once every day at the same time. When using this option, enter the time to
perform the daily transmission in the Start field.