ADS XiLog+ System User Manual

37

Send Data Reports

Selecting this option ensures the logger sends data reports by SMS or GPRS
based on the frequency selected for remote data reporting.

The minimum logging interval for data sent through SMS is 1 minute.
Activating SMS reporting for data based on a shorter logging interval requires
averaging the data at a 1-minute interval before being sent.

Note: Sending data logged at an interval of less than 15 minutes
through SMS requires sending more than one SMS per day for each
channel. For example, sending 1-minute SMS data every day requires
sending 15 SMS per channel per day.

Secondary Logging Interval

Some XiLog+ models allow a secondary logging interval for logging the same
channel input at a second rate. This data can be reported remotely, or logged
internally and remotely requested (as required).